How to modify the files of the machine by means of RDworks? / Daniel
To
manage the files that are stored in the memory of the operation panel with the
RDWORKS software, follow the next steps
1. Open
the RDworks program and connect the machine's USB cable to the USB computer
port, by default the “Work” menu is activated in the work system bar
2. To change the menu click on the "Doc" menu
3. Move
the process control bar to display the “Doc” menu control buttons
4. Press the “Read”
button to read the files that the machine has
5. You can clean all files by pressing “Delete all”
6. You can delete files One by one by selecting each file and
pressing “Delete”
You can also remove the number of duplicate copies of each
file, selecting the duplicate file and pressing the "Modify Number"
button, change the value to 1 and press the "set" button,
or you can activate
"All files" and change to 1 value to delete all copies of All files
To download the file that you have in the memory of the
machine press "Download", you can save it on the hard disk of the
computer, modify and load with the option "Upload"
Related Articles
How to delete all the files of the machine using RDworks? / Daniel
To delete all the files that are stored in the memory of the operation panel with the RDWORKS software, follow the next steps 1. Open the RDworks program and connect the machine's USB cable to the USB computer port, by default the “Work” menu ...
5 - RDworks software installation / Daniel
To install the RDWorks Software follow the steps Step 1 Download the software Version 8.01.60 from this link (copy and paste) https://www.dropbox.com/sh/e3444th055hvq5c/AAAtZEqaCp3Of27V7OMog-w8a?dl=0 link of the version RDworks V 8.0.1.61 ...
RDworks Ethernet and Wifi PC Connection / Daniel
CONNECTION THROUGH A WIRELESS ROUTER AND ETHERNET CABLE For this connection, you need a wireless router that allows you to route the computer and the Ethernet connection of the Ruida board STEP 1 Connect the computer to the router through the ...
RDWORKS POINT-TO-POINT ETHERNET CABLE CONNECTION / Daniel
POINT-TO-POINT CONNECTION THROUGH A NETWORK UTP CABLE WITH RJ45 CONNECTOR To make the connection of our CO2 Cutting and Engraving Equipment that has a Ruida controller board through the Ethernet connection, we will need an Ethernet Network cable with ...
How to change the units from mm to inches in Rdworks software? / Daniel
To change the units from mm to inches in Rdworks software follow this steps Step 1 Go to Config menu /file para Settings/ ( Rdworks Old version) Or Config Menu / System setting / Import-Export (Rdworks New Version) Step 2 Change DXF unit, Unit ...