Interface Connection IPG Laser Source (3.0kW – 6.0kW) / Juan David

Interface Connection IPG Laser Source (3.0kW – 6.0kW) / Juan David

Interface Connection IPG Laser Source (3.0kW – 6.0kW)

The following are the instruction to connect and make the interface cable for data

communication between IPG Laser Source to the machine:

1. From Main Board in OUT 5 (NO) make a wire cable to pin number 8 of the connector

2. From Main Board in OUT 5 (CON) make a wire cable to pin number 9 of the connector

3. From Main Board in OUT 6 (NO) make a wire cable to pin number 10 of the connector

4. From Main Board in OUT 6 (CON) make a wire cable to pin number 11 of the connector

5. From PWM+ make a wire cable to pin number 15

6. From PWM- make a wire cable to number 16

7. Make a short circuit between pin number 1 and 4

8. Make a short circuit between pin number 2 and 3

The connector needs to be welded the pin connector and will be like the following image